Event ID 654Password hash sync heartbeat ended
Heartbeat finished. Logged every 30 minutes per AD connector when the channel is active and no changes are pending.
| Log | Application |
|---|---|
| Source | Directory Synchronization |
| Area | Entra Connect |
What to check
No 654 for a connector means the channel is not working; check for 611, 652 or 655.
Find it with PowerShell
Run on the machine that logs it.
Get-WinEvent -FilterHashtable @{ LogName = 'Application'; Id = 654 } -MaxEvents 50 |
Format-List TimeCreated, Id, MessageHunt for it in Sentinel or Log Analytics
This works once a data collection rule sends the Application log to your workspace, where it lands in the Event table.
Event
| where TimeGenerated > ago(7d)
| where EventLog == "Application" and EventID == 654
| project TimeGenerated, Computer, Source, RenderedDescription
| order by TimeGenerated descRelated Entra Connect events
- Event ID 601: Password hash sync manager starting
- Event ID 607: Password hash sync could not start
- Event ID 609: Password hash sync stopped
- Event ID 611: Error during password hash sync for a domain
- Event ID 613: Paused: full sync not completed
- Event ID 616: Connection to preferred DC failed
- Event ID 617: Full password hash sync started for forest
- Event ID 621: Full password hash sync attempt failed