← cd ~/events
// events/611 · Entra Connect
Event ID 611Error during password hash sync for a domain
Password hash sync failed for a domain. Often a DC replication (DRS) RPC error, which the message shows.
| Log | Application |
|---|---|
| Source | Directory Synchronization |
| Area | Entra Connect |
What to check
Read the exception text. Microsoft treats 611 as a connectivity problem with the named forest; some older RPC errors were fixed by updating the sync tool.
Find it with PowerShell
Run on the machine that logs it.
Get-WinEvent -FilterHashtable @{ LogName = 'Application'; Id = 611 } -MaxEvents 50 |
Format-List TimeCreated, Id, MessageHunt for it in Sentinel or Log Analytics
This works once a data collection rule sends the Application log to your workspace, where it lands in the Event table.
Event
| where TimeGenerated > ago(7d)
| where EventLog == "Application" and EventID == 611
| project TimeGenerated, Computer, Source, RenderedDescription
| order by TimeGenerated descRelated Entra Connect events
- Event ID 601: Password hash sync manager starting
- Event ID 607: Password hash sync could not start
- Event ID 609: Password hash sync stopped
- Event ID 613: Paused: full sync not completed
- Event ID 616: Connection to preferred DC failed
- Event ID 617: Full password hash sync started for forest
- Event ID 621: Full password hash sync attempt failed
- Event ID 622: Full password hash sync completed for a domain