azureblog.co.uk
← cd ~/events
// events/609 · Entra Connect

Event ID 609Password hash sync stopped

Password hash sync has stopped.

LogApplication
SourceDirectory Synchronization
AreaEntra Connect

What to check

If unexpected, check whether the server is in staging mode or the service has stopped.

Find it with PowerShell

Run on the machine that logs it.

powershell2 lines
Get-WinEvent -FilterHashtable @{ LogName = 'Application'; Id = 609 } -MaxEvents 50 |
    Format-List TimeCreated, Id, Message

Hunt for it in Sentinel or Log Analytics

This works once a data collection rule sends the Application log to your workspace, where it lands in the Event table.

kql5 lines
Event
| where TimeGenerated > ago(7d)
| where EventLog == "Application" and EventID == 609
| project TimeGenerated, Computer, Source, RenderedDescription
| order by TimeGenerated desc

Related Entra Connect events

Search all 123 event IDs →